#E35
Q: What settings should I use for the loads and DCPMU?
DCPMU and ETS Loads
|
DC Parametrics
Loads as Pull-ups for Open Collector For Open Collector Output situations, look at the circuit in the device spec that is recommended for loading. The IOH value is easy; just put some small amount of current such as 1 or 2mA. The resistor value in the device spec circuit for pull-up will dictate the current for IOL. This is the most sensitive value for the loads and often must be tweaked while you observe device performance under test. It all depends on how much drive the device has. Here are some common starting values:
IOH: 2mA Commutation Voltage = Logic hi Programmable Loads don't always perform like resistive pull-ups, but you may be able to avoid mounting a forest of resistors on your DUT board if you have the patience to try loads first. Z t If measuring time-to-tristate, the comm voltage is usually set to or near the rail of the desired measurement transition:
For Lo-to-Z, Comm = Lo Parallel Loads The parallel load feature provides a voltage potential for DUT output pins through a 50 ohm resistor. How is this done? Essentially, ETS2k simply enables the unused driver to drive the programmed voltage potential onto the tester channel. Remember that the driver provides 50mA of drive current, so your DUT outputs must be able to overcome that force in order to get the output data to the ETS receiver. You cannot use the parallel loads if the pin is defined as an input or an I/O pin (bidirectional) because ETS drivers cannot change logic levels on the fly. |
Q'nApp #E9:Iddq testing Q'nApp#E20: Power andGround Q'nApp #E25: ETS Drivers and Receivers Q'nApp #E45: Pin-to-Pin continuity Q'nApp #E51: Fast continuity Qe35.zip is a zipped Word file of this Q'nApp. Click your browser's Back button to return to the Q'nApps index. |